mirror of
https://github.com/superseriousbusiness/gotosocial.git
synced 2025-10-29 17:22:24 -05:00
- codeberg.org/gruf/go-ffmpreg: v0.6.9 -> v0.6.10
- github.com/ncruces/go-sqlite3: v0.27.1 -> v0.28.0
- github.com/stretchr/testify: v1.10.0 -> v1.11.1
- github.com/tdewolff/minify/v2 v2.23.11 -> v2.24.2
- go.opentelemetry.io/otel{,/*}: v1.37.0 -> v1.38.0
- go.opentelemetry.io/contrib/*: v0.62.0 -> v0.63.0
Reviewed-on: https://codeberg.org/superseriousbusiness/gotosocial/pulls/4406
Co-authored-by: kim <grufwub@gmail.com>
Co-committed-by: kim <grufwub@gmail.com>
277 lines
8.4 KiB
Go
277 lines
8.4 KiB
Go
// Copyright The OpenTelemetry Authors
|
||
// SPDX-License-Identifier: Apache-2.0
|
||
|
||
package log // import "go.opentelemetry.io/otel/sdk/log"
|
||
|
||
import (
|
||
"context"
|
||
"errors"
|
||
"sync"
|
||
"sync/atomic"
|
||
|
||
"go.opentelemetry.io/otel"
|
||
"go.opentelemetry.io/otel/internal/global"
|
||
"go.opentelemetry.io/otel/log"
|
||
"go.opentelemetry.io/otel/log/embedded"
|
||
"go.opentelemetry.io/otel/log/noop"
|
||
"go.opentelemetry.io/otel/sdk/instrumentation"
|
||
"go.opentelemetry.io/otel/sdk/resource"
|
||
)
|
||
|
||
const (
|
||
defaultAttrCntLim = 128
|
||
defaultAttrValLenLim = -1
|
||
|
||
envarAttrCntLim = "OTEL_LOGRECORD_ATTRIBUTE_COUNT_LIMIT"
|
||
envarAttrValLenLim = "OTEL_LOGRECORD_ATTRIBUTE_VALUE_LENGTH_LIMIT"
|
||
)
|
||
|
||
type providerConfig struct {
|
||
resource *resource.Resource
|
||
processors []Processor
|
||
fltrProcessors []FilterProcessor
|
||
attrCntLim setting[int]
|
||
attrValLenLim setting[int]
|
||
allowDupKeys setting[bool]
|
||
}
|
||
|
||
func newProviderConfig(opts []LoggerProviderOption) providerConfig {
|
||
var c providerConfig
|
||
for _, opt := range opts {
|
||
c = opt.apply(c)
|
||
}
|
||
|
||
if c.resource == nil {
|
||
c.resource = resource.Default()
|
||
}
|
||
|
||
c.attrCntLim = c.attrCntLim.Resolve(
|
||
getenv[int](envarAttrCntLim),
|
||
fallback[int](defaultAttrCntLim),
|
||
)
|
||
|
||
c.attrValLenLim = c.attrValLenLim.Resolve(
|
||
getenv[int](envarAttrValLenLim),
|
||
fallback[int](defaultAttrValLenLim),
|
||
)
|
||
|
||
return c
|
||
}
|
||
|
||
// LoggerProvider handles the creation and coordination of Loggers. All Loggers
|
||
// created by a LoggerProvider will be associated with the same Resource.
|
||
type LoggerProvider struct {
|
||
embedded.LoggerProvider
|
||
|
||
resource *resource.Resource
|
||
processors []Processor
|
||
fltrProcessors []FilterProcessor
|
||
attributeCountLimit int
|
||
attributeValueLengthLimit int
|
||
allowDupKeys bool
|
||
|
||
loggersMu sync.Mutex
|
||
loggers map[instrumentation.Scope]*logger
|
||
|
||
stopped atomic.Bool
|
||
|
||
noCmp [0]func() //nolint: unused // This is indeed used.
|
||
}
|
||
|
||
// Compile-time check LoggerProvider implements log.LoggerProvider.
|
||
var _ log.LoggerProvider = (*LoggerProvider)(nil)
|
||
|
||
// NewLoggerProvider returns a new and configured LoggerProvider.
|
||
//
|
||
// By default, the returned LoggerProvider is configured with the default
|
||
// Resource and no Processors. Processors cannot be added after a LoggerProvider is
|
||
// created. This means the returned LoggerProvider, one created with no
|
||
// Processors, will perform no operations.
|
||
func NewLoggerProvider(opts ...LoggerProviderOption) *LoggerProvider {
|
||
cfg := newProviderConfig(opts)
|
||
return &LoggerProvider{
|
||
resource: cfg.resource,
|
||
processors: cfg.processors,
|
||
fltrProcessors: cfg.fltrProcessors,
|
||
attributeCountLimit: cfg.attrCntLim.Value,
|
||
attributeValueLengthLimit: cfg.attrValLenLim.Value,
|
||
allowDupKeys: cfg.allowDupKeys.Value,
|
||
}
|
||
}
|
||
|
||
// Logger returns a new [log.Logger] with the provided name and configuration.
|
||
//
|
||
// If p is shut down, a [noop.Logger] instance is returned.
|
||
//
|
||
// This method can be called concurrently.
|
||
func (p *LoggerProvider) Logger(name string, opts ...log.LoggerOption) log.Logger {
|
||
if name == "" {
|
||
global.Warn("Invalid Logger name.", "name", name)
|
||
}
|
||
|
||
if p.stopped.Load() {
|
||
return noop.NewLoggerProvider().Logger(name, opts...)
|
||
}
|
||
|
||
cfg := log.NewLoggerConfig(opts...)
|
||
scope := instrumentation.Scope{
|
||
Name: name,
|
||
Version: cfg.InstrumentationVersion(),
|
||
SchemaURL: cfg.SchemaURL(),
|
||
Attributes: cfg.InstrumentationAttributes(),
|
||
}
|
||
|
||
p.loggersMu.Lock()
|
||
defer p.loggersMu.Unlock()
|
||
|
||
if p.loggers == nil {
|
||
l := newLogger(p, scope)
|
||
p.loggers = map[instrumentation.Scope]*logger{scope: l}
|
||
return l
|
||
}
|
||
|
||
l, ok := p.loggers[scope]
|
||
if !ok {
|
||
l = newLogger(p, scope)
|
||
p.loggers[scope] = l
|
||
}
|
||
|
||
return l
|
||
}
|
||
|
||
// Shutdown shuts down the provider and all processors.
|
||
//
|
||
// This method can be called concurrently.
|
||
func (p *LoggerProvider) Shutdown(ctx context.Context) error {
|
||
stopped := p.stopped.Swap(true)
|
||
if stopped {
|
||
return nil
|
||
}
|
||
|
||
var err error
|
||
for _, p := range p.processors {
|
||
err = errors.Join(err, p.Shutdown(ctx))
|
||
}
|
||
return err
|
||
}
|
||
|
||
// ForceFlush flushes all processors.
|
||
//
|
||
// This method can be called concurrently.
|
||
func (p *LoggerProvider) ForceFlush(ctx context.Context) error {
|
||
if p.stopped.Load() {
|
||
return nil
|
||
}
|
||
|
||
var err error
|
||
for _, p := range p.processors {
|
||
err = errors.Join(err, p.ForceFlush(ctx))
|
||
}
|
||
return err
|
||
}
|
||
|
||
// LoggerProviderOption applies a configuration option value to a LoggerProvider.
|
||
type LoggerProviderOption interface {
|
||
apply(providerConfig) providerConfig
|
||
}
|
||
|
||
type loggerProviderOptionFunc func(providerConfig) providerConfig
|
||
|
||
func (fn loggerProviderOptionFunc) apply(c providerConfig) providerConfig {
|
||
return fn(c)
|
||
}
|
||
|
||
// WithResource associates a Resource with a LoggerProvider. This Resource
|
||
// represents the entity producing telemetry and is associated with all Loggers
|
||
// the LoggerProvider will create.
|
||
//
|
||
// By default, if this Option is not used, the default Resource from the
|
||
// go.opentelemetry.io/otel/sdk/resource package will be used.
|
||
func WithResource(res *resource.Resource) LoggerProviderOption {
|
||
return loggerProviderOptionFunc(func(cfg providerConfig) providerConfig {
|
||
var err error
|
||
cfg.resource, err = resource.Merge(resource.Environment(), res)
|
||
if err != nil {
|
||
otel.Handle(err)
|
||
}
|
||
return cfg
|
||
})
|
||
}
|
||
|
||
// WithProcessor associates Processor with a LoggerProvider.
|
||
//
|
||
// By default, if this option is not used, the LoggerProvider will perform no
|
||
// operations; no data will be exported without a processor.
|
||
//
|
||
// The SDK invokes the processors sequentially in the same order as they were
|
||
// registered.
|
||
//
|
||
// For production, use [NewBatchProcessor] to batch log records before they are exported.
|
||
// For testing and debugging, use [NewSimpleProcessor] to synchronously export log records.
|
||
//
|
||
// See [FilterProcessor] for information about how a Processor can support filtering.
|
||
func WithProcessor(processor Processor) LoggerProviderOption {
|
||
return loggerProviderOptionFunc(func(cfg providerConfig) providerConfig {
|
||
cfg.processors = append(cfg.processors, processor)
|
||
if f, ok := processor.(FilterProcessor); ok {
|
||
cfg.fltrProcessors = append(cfg.fltrProcessors, f)
|
||
}
|
||
return cfg
|
||
})
|
||
}
|
||
|
||
// WithAttributeCountLimit sets the maximum allowed log record attribute count.
|
||
// Any attribute added to a log record once this limit is reached will be dropped.
|
||
//
|
||
// Setting this to zero means no attributes will be recorded.
|
||
//
|
||
// Setting this to a negative value means no limit is applied.
|
||
//
|
||
// If the OTEL_LOGRECORD_ATTRIBUTE_COUNT_LIMIT environment variable is set,
|
||
// and this option is not passed, that variable value will be used.
|
||
//
|
||
// By default, if an environment variable is not set, and this option is not
|
||
// passed, 128 will be used.
|
||
func WithAttributeCountLimit(limit int) LoggerProviderOption {
|
||
return loggerProviderOptionFunc(func(cfg providerConfig) providerConfig {
|
||
cfg.attrCntLim = newSetting(limit)
|
||
return cfg
|
||
})
|
||
}
|
||
|
||
// WithAttributeValueLengthLimit sets the maximum allowed attribute value length.
|
||
//
|
||
// This limit only applies to string and string slice attribute values.
|
||
// Any string longer than this value will be truncated to this length.
|
||
//
|
||
// Setting this to a negative value means no limit is applied.
|
||
//
|
||
// If the OTEL_LOGRECORD_ATTRIBUTE_VALUE_LENGTH_LIMIT environment variable is set,
|
||
// and this option is not passed, that variable value will be used.
|
||
//
|
||
// By default, if an environment variable is not set, and this option is not
|
||
// passed, no limit (-1) will be used.
|
||
func WithAttributeValueLengthLimit(limit int) LoggerProviderOption {
|
||
return loggerProviderOptionFunc(func(cfg providerConfig) providerConfig {
|
||
cfg.attrValLenLim = newSetting(limit)
|
||
return cfg
|
||
})
|
||
}
|
||
|
||
// WithAllowKeyDuplication sets whether deduplication is skipped for log attributes or other key-value collections.
|
||
//
|
||
// By default, the key-value collections within a log record are deduplicated to comply with the OpenTelemetry Specification.
|
||
// Deduplication means that if multiple key–value pairs with the same key are present, only a single pair
|
||
// is retained and others are discarded.
|
||
//
|
||
// Disabling deduplication with this option can improve performance e.g. of adding attributes to the log record.
|
||
//
|
||
// Note that if you disable deduplication, you are responsible for ensuring that duplicate
|
||
// key-value pairs within in a single collection are not emitted,
|
||
// or that the telemetry receiver can handle such duplicates.
|
||
func WithAllowKeyDuplication() LoggerProviderOption {
|
||
return loggerProviderOptionFunc(func(cfg providerConfig) providerConfig {
|
||
cfg.allowDupKeys = newSetting(true)
|
||
return cfg
|
||
})
|
||
}
|